Beijing KES Biology Technology Co., Ltd.

Beijing KES Biology Technology Co., Ltd. Global Medical & Aesthetic equipment Manufacture Email:info@keslaser.com

Manufacturer from China
Verified Supplier
14 Years
Home / Products / Elight Laser /

IPL Radio Frequency Therapy Laser Equipment with IC Card / Approved with 2000W

Contact Now
Beijing KES Biology Technology Co., Ltd.
Visit Website
City:beijing
Province/State:beijing
Country/Region:china
Contact Person:MissJackie
Contact Now

IPL Radio Frequency Therapy Laser Equipment with IC Card / Approved with 2000W

Ask Latest Price
Video Channel
Place of Origin :China
Brand Name :KES
Model Number :MED-130C
Certification :Medical CE, CE Certificate, ISO13485, FDA Pending
MOQ :3 units
Price :USD1~
Packaging Details :Aluminium Packing Box
Delivery Time :14 working days
Payment Terms :T/T,
Supply Ability :800 units per month
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

IPL Radio Frequency Therapy Laser Equipment with IC Card / Approved with 2000W

Model No: MED-130C



Product Description


Working Principle:
SHR=Super Hair Removal,it’s a revolutionary technology of hair removal which is having a sweeping success. (adopt technology AFT,EDF)

SHR combines laser technology and the benefits of the pulsating light method achieving practically painless results.

SHR combined with “In Motion” represents a breakthrough in permanent hair removal with light technology. The treatment is more pleasant than with the conventional systems and your skin is better protected.



Before & After:


Unique Advantages:

1) SHR+ E-light 2 handpieces on one unit
2) Fast treatment. Frequency up to 10Hz!
3) Big spot size: 15*50mm
4) Painless: new AFT technology (Advanced Fluorescence Technology) uses low and equal energy. The special filter cut s 950-1200nm wavelength, which is useless in treatment and absorbs water to make patient feel painless
5) Hairfree, even on work on blonde, red or fine hair
6) Skinfree, suitable for all skin types, even tanners
7) Accurate Software control and parameters adjustable

IPL Radio Frequency Therapy Laser Equipment with IC Card / Approved with 2000W

Difference Of IPL SHR & Traditional IPL or laser:

Traditional laser or IPL technologies employ short impulses of approximately 2-300 milliseconds, applying a vast amount of energy (12-120 J/cm2). Energy is transported to the hair root through melanin, where warmth of 65-72° Celsius is produced. Energy reaches the root of the hair follicle solely through melanin. Skin and red blood cells have a similar absorption coefficient as melanin and therefore also absorb the high levels of energy produced by the laser and IPL methods.

SHR technology, on the other hand, utilizes the melanin path only partially (50%)., and combining In-Motion technology, gently warms the skin helping penetrate down to the follicles which produce hair growth.

Research has shown that a slower, but longer heating process is considerably more effective for permanent hair removal than high and short levels of energy. Therefore, when using SHR, the device is passed over the tissue multiple times (in motion) using low energy but a high rate of repetition (up to 10Hz, i.e. 10 times per second) instead of using the traditional method with single, high-energy impulses. Thus, the hair melanin, as well as the tissue of the stem cells, is heated with low energy at a slow pace and over a longer period of time to a comfortable temperature of 45° Celsius.

Comparison:

Parameter Normal IPL MED-130CAdvantages
Pulse

Multi pulse mode
1-6/1-15pulses

Single pulse Single pulse mode can emit energy averagely, but multi-pulse mode focus energy on first pulse, very easy to burn skin
Wavelength HR: 640-1200nm HR:650-950nm Moving IPL filtered violet light and infrared light, which will eradiate and absorb water from target skin. So moving IPL does not have any side-effect to body.
DEC TechnologyUnavailableAvailableMake sure energy output accurate and same with the display all the time, which makes operation easy and safe.

Particle filter
& De-ionizer filter

UnavailableAvailableProlong lifespan of handpiece and machine!
Frequency0.2-1Hz1-10HzSpeed up the treatment, save time
Work technologyStationary technologyStationary technology & In-motion technologyMoving IPL can use less time to do treatment on back, leg and arm.
Power supply1200W2400WMake fast charging and achieve fast shooting
Timerno30sAccurate control the time and convenient for operator
Spot size10*40mm15*50mmBiger size increase the efficiency
Operation Interface7.4” interface8.4” intelligent interfaceMore easy for operator



Technical Specifications:

Wavelength (Spectrum)

650-950nm;
430/590/750-1200nm

Energy Density (Fluence)

1-26J/cm2(SHR)
1-60J/cm2(Normal)

Spot Size

15x50mm² (SHR)
15*35mm2 (interchangeable)

Pulse duration1-15ms
Pulse Single
Pulse Repetition Rate1-10Hz
Timer1-30s
IPL Peak Power2400W
CoolingContinuous Crystal contact cooling (-4°C~4°C ) + Air cooling + Closed water circulation cooling
Stand-by WorkingContinuously for 12 hours
Display8.4" True Color LCD Touch Screen(Intelligent operation)
Electrical Requirements100-240VAC, 20A max., 50/60Hz
Net Weight52kgs
Dimensions (WxDxH)55*48*109cm