Beijing KES Biology Technology Co., Ltd.

Beijing KES Biology Technology Co., Ltd. Global Medical & Aesthetic equipment Manufacture Email:info@keslaser.com

Manufacturer from China
Verified Supplier
14 Years
Home / Products / Elight Laser /

Medical CE Approved E-Light IPL RF Beauty Equipment For Wrinkle Removal

Contact Now
Beijing KES Biology Technology Co., Ltd.
Visit Website
City:beijing
Province/State:beijing
Country/Region:china
Contact Person:MissJackie
Contact Now

Medical CE Approved E-Light IPL RF Beauty Equipment For Wrinkle Removal

Ask Latest Price
Video Channel
Place of Origin :China
Brand Name :KES
Model Number :MED-140C+
Certification :Medical CE, CE Certificate, ISO13485, SGS, FDA Pending
MOQ :1 units
Packaging Details :Aluminium Packing Box
Delivery Time :7 working days
Payment Terms :T/T, , Western Union, MoneyGram
Supply Ability :800 units per month
Color :White+Grey
Handpiece :IPL, E liht and SHR 3 handpiece
Power supply :2000W
Screen :10.4 inch color touch screen
capacitors :3 Japan customized capacitors
spot size :10*40mm2; 15*50mm2; 15*35mm2
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Medical CE Approved E-light IPL RF Beauty Equipment for Wrinkle Removal

Applications


750-1200nmHair Removal (Skin Type IV)
690-1200nmHair Removal (Skin Type III)
640-1200nmHair Removal (Skin Type I & II ) ; Wrinkle Removal
590-1200nmPigmentation and Vascularity; Skin Rejuvenation
560-1200nmVascular and Pigmented Lesions; Skin Rejuvenation
530-1200nmSkin Rejuvenation; Superficial Vascular Lesions
510-1200nmSuperficial Vascular Lesions
480-1200nmLight Pigmentation
430-1200nmAcne
RF TreatmentSkin Tightening and Face Lifting


Medical CE Approved E-Light IPL RF Beauty Equipment For Wrinkle Removal

How it works?


E-Light is the perfect combination of IPL technology with Bi-polar Radio Frequency (RF) and Skin Contact Cooling.
Radio Frequency is independent of melanin and thus independent of skin type. With Radio Frequency, increased selectivity and deeper dermal penetration would be achieved, thus lower energy is applied during the IPL treatment. Uncomfortable feeling during the IPL treatment will be decreased significantly and better result can be expected. That is, less optical energy (IPL), when synergistically combined with Bi-polar RF, improves the safety factor when treating all skin types.
Meanwhile, contacting surface cooling technology applied on the treatment probe head can eliminate the heat effect attributed to optical energy, and increase the resistance of surface skin, reduce the RF absorption of the surface skin, greatly improving both the treatment performance and safety. The technology is equally applicable and effective to mild color target tissues.

Medical CE Approved E-Light IPL RF Beauty Equipment For Wrinkle Removal

Before And After

Medical CE Approved E-Light IPL RF Beauty Equipment For Wrinkle Removal

Unique Advantages


SHR mode:10 times/s
Intelligent + Professional mode = parameters setting automatically
Appearance design make excellent cooling
Strong system with 3 Capacitors and 2 power supplies!

Technical Specifications

Wavelength (Spectrum)

650-950nm(HR)
510-1200nm(SR) ,
430/530/640-1200nm (15*35mm)

Energy Density (Fluence)

1-26J/cm2(SHR)
1-60J/cm2(Normal)

Spot Size

15x50mm2 (HR);
10x40mm2 (SR);
15*35mm2 (interchangeable)

Pulse duration1-15ms
PulseSingle
Pulse Repetition Rate1-10Hz
Timer1-30s
IPL Peak Power2500W
CoolingContinuous Crystal contact cooling (-4°C-2°C ) + Air cooling + Closed water circulation cooling
Stand-by WorkingContinuously for 18 hours
Display10.4" True Color LCD Touch Screen
Electrical Requirements100-240VAC, 20A max., 50/60Hz
Net Weight60 kgs
Dimensions (WxDxH)

63*53*126cm


How to use IPL ?

Step 1: Remove all visible hair in the area you wish to treat with your preferred hair removal method. If desired, the Braun Skin i·expert Smart IPL includes a Venus razor for easy surface hair removal. Ensure there is no hair remaining above the surface of the skin. Then pat your skin dry.

Step 2: select the standard head or the precision head depending on the size of the area you wish to treat. Plug in the Skin i·expert Smart IPL.

Step 3: Put the nozzle in full contact with the skin to make sure the product works correctly. If the light flashes white, a valid skin tone is detected. If not in proper contact with the skin, the device will not flash. In the case of a red light, there is not full contact or it is an invalid skin tone.

Step 4: For larger body areas use gliding mode: hold down the treatment button and glide along your skin. For smaller areas, press and release the treatment button. For sensitive areas or if it’s your first time, you can use the gentle or extra gentle mode.

Step 5: It is important to wipe clean the nozzle after every use.

Step 6: In the first phase of your treatment, treat once a week for 4 - 12 weeks. Then adjust to your needs (i.e. every 1-2 months).